1.1.1 Surface Mount Units Surface mount units can be mounted directly to a wall or pilaster, or can be post mounted using a DoorKing heavy-duty mount
1.1.2 Surface Mount Units with Recess Box Surface mount units can be semi-flush mounted into a wall or pilaster by using the optional recess-mounting
1.1.3 Flush Mount Units Flush mount units are installed into a wall with flush mount kits 1814-065 (stainless) or 1814-066 (gold). Flush mount kits
1.1.4 Flush Mount Rough-in Box The flush mount installation kit has two parts; the rough-in box and the trim ring. The rough-in box is installed fir
1.1.5 Flush Mount Trim Ring Flush mount units can be mounted by using the 1814-065 (stainless) or 1814-066 (gold) mounting kit. Flush mounting kits
1.1.6 Flush Mount Surface Mounting Kit Flush mount units can be surface mounted by using the optional 1814-152 surface mount trim ring. Flush mount
1.1.7 Wall Mount Units Wall mount units (models 1815 and 1817 only) are designed to be mounted directly onto a wall without the need of cutting a lar
1.2 MEMORY CHIP INSTALLATION The telephone entry system is shipped with two memory chips packaged in a separate box inside the shipping container.
1.3 POSTAL LOCK INSTALLATION At some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they c
SECTION 2 – WIRING Prior to installing wiring to the telephone entry system, we suggest that you become familiar with the instructions, illustrations
16 VAC20 VARS-232 Input(OPTIONAL)Connections to 2348Elevator Control Board(OPTIONAL)Inputs for weigandcontrol devices(OPTIONAL)16 VAC20 VAWeigand Powe
2.1 MAIN TERMINAL DESCRIPTION TERMINAL DESCRIPTION 1 Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 2
There are four (4) auxiliary terminals on the 1840 control board which provide inputs for: weigand data, elevator control, RS232 communication, and p
2.2.3 Elevator Control Terminals The elevator control terminals are used when the 2348-010 elevator control board is connected to the system to enabl
2.3 RELAY WIRING (TYPICAL) 2.3.1 Controlling a Single Door or Gate Relay 1 is typically used when the system will control a single door or vehicula
2.3.2 Controlling a Gate Operator and Pedestrian Gate (or Door) When controlling a gate operator and pedestrian gate (or door), relay 1 is typically
2.3.3 Controlling a Gate Operator and Two Pedestrian Doors (or Gates) The diagram below shows how it is possible to control a gate operator and two p
2.3.4 Tracker Expansion Board Control When Tracker expansion boards are used with the system to control up to 16 additional entry points, relays 1 an
28
SECTION 3 – PROGRAMMING IMPORTANT! Many of the advanced features available with this telephone entry system cannot be programmed from the system key
3 Use this manual with the following models only. All 1803PC models with circuit board 1844-010 REV A and B. All 1815 models with circuit board 1840
3.1.2 Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with s
3.1.3 System Memory Prior to starting the programming of the PC programmable telephone entry system, you must know the memory capacity and the type of
3.2 PROGRAMMING WITH A PC Prior to programming the PC Programmable Telephone Entry System with the DoorKing Remote Account Manager for Windows softw
3.2.3 Programming for Call-up Operation This feature is only used when the telephone entry system is interfaced with a DoorKing 1816 Telephone Interc
3.3 GENERAL PROGRAMMING Proceed with the programming steps on the following pages only if PC programming will not be used. 3.3.1 Relay Strike Tim
3.3.3 Tone Open Numbers These steps will program the tone open numbers for relays 0, 1 and 2. You will need to enter a four-digit number (see chart
3.3.5 Touch-tone / Rotary-dial This programming sequence will set the telephone entry system to dial out in either a touch-tone or rotary format. Ge
3.4 PROGRAMMING LETTERS, NUMBERS and MESSAGES These programming steps apply only to the 1815 and 1817 systems. The keypad on the 1815 and 1817 syst
3.4.2 Programming the User Message – 1815 Systems The user message, followed by the instruction message, scrolls across the screen from right to left
3.4.3 Programming the Instruction Message – 1815 Systems The instruction message scrolls across the screen from right to left when the system is not
TABLE OF CONTENTS Preface Important Notices...
3.4.4 Programming the User Message – 1817 Systems The user message is displayed on the top screen of the 1817. This message can be a maximum of 80 c
3.4.5 Programming the Instruction Message – 1817 Systems The instruction message is displayed on the bottom screen of the 1817. This message can be
Before beginning manual programming of this telephone entry system from the keypad, it is strongly recommended that the resident log sheets in the ba
3.5.1 Programming the Directory Code Length This programming sequence sets the directory code length to 1 - 2 - 3 or 4 digits. If 11 or more residen
3.5.3 Programming Area Codes Up to 10 different area codes can be programmed for any 10-digit or long distance calling requirements and will be refer
3.5.5 Programming Names (1815, 1817 Systems Only) In this section, names will be programmed into the system. Names are referenced to a phone number
3.5.8 Delete Area Codes This program sequence deletes area code numbers that have been programmed into the system. 1. Press *24 and enter the four-
3.6 PROGRAMMING DEVICE CODES The PC programmable telephone entry system must be equipped with a MemPLUS chip to program device codes into its memory
3.7 FOUR-DIGIT ENTRYT CODES Four-digit entry codes are entered on the system keypad preceded by # to allow the resident access. Do not confuse four
SECTION 4 – ADJUSTMENTS 4.1 Speaker Volume 1. Open the front of the telephone entry system and locate the speaker volume adjustment. 2. Place a pho
3.4 Programming Letters, Numbers and Messages 3.4.1 Programming Letters and Numbers ...
4.6 Back-light Cutoff (1817 Only) 1. The back-light cutoff potentiometer is located on the LCD control board in the 1817 system only. This adjustm
1815 Adjustment Locations SEC LEVELCLICK SENSVOLUMEFEEDBACKMASTERCODERING PINRLY 2AUTO1816HFHSCONTRAST 51
1817 Adjustment Locations SEC LEVELCLICK SENSVOLUMEFEEDBACKMASTERCODERING PINRLY 2AUTO1816HFHSBACK LIGHTCONTRASTUPPERCONTRASTLOWER 52
SECTION 5 – OPERATING INSTRUCTIONS 5.1 Guest Instructions Instructions on the telephone entry systems guide guest on the usage of the system and how
5.2 RESIDENT INSTRUCTIONS Resident control of the door or gate that the telephone entry system controls is limited to opening the door or gate in res
5.3 SYSTEM ADMINISTRATOR The administrator can perform the following operations from a remote location using a touch tone telephone. You must know t
5.3.3 Relay Check The telephone entry system can be called and a check can be made to determine if any of the relays in the system are in a "ho
5.4 MISCELLANEOUS OPERATING INSTRUCTIONS 5.4.1 Talk Time The talk time for directory codes 0, 00, 000, 0000 and 1, 01, 001, 0001 is factory set to
SECTION 6 – MAINTENANCE The DoorKing telephone entry system is essentially a maintenance free device. When the unit is properly installed, it should
IMPORTANT NOTICE FCC - UNITED STATES This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Par
SYMPTON POSSIBLE SOLUTION(S) Cannot get into programming mode. • Wrong master code entered. Start over. • Waiting too long between pushing buttons.
SYMPTON POSSIBLE SOLUTION(S) Four-digit entry codes will not work. • Forgetting to press # first. • Re-program the entry code ranges (3.7.3). Entry
6.1.2 Weigand Test (1815, 1817 Systems Only) This programming sequence will allow you to view the weigand data on the display as it is received by th
6.1.4 Elevator Board / Floor Hardware Test This testing sequence will allow you to check activation of individual relays on the elevator control boar
6.2 ACCESSORIES Surface Trim Ring Use to recess a surface mount unit into a wall or column. P/N 1803-150. Flush Kit Use to install flush style un
Complete the information in the tables on the following pages to maintain a record of the information that has been programmed into the telephone ent
NAME AAC PHONE NUMBER DIR CODE ENT CODE DEVICE CODE SEC LEVEL FL ER
Resident Instruction Sheet Your building / community has been equipped with a DoorKing Telephone Entry System that will provide communication for y
GENERAL INFORMATION • Prior to beginning the installation of the telephone entry system, we suggest that you become familiar with the instructions,
FEATURES • Can provide service for up to 3000 residents and can store up to 8000 card, transmitter or digital PIN codes when ordered with 3000 MemPL
SECTION 1 - INSTALLATION Order your telephone line at least two weeks prior to the planned installation date. This will assure that a phone line is